Công ty TNHH kỹ thuật công nghệ và dịch vụ Tiên Phong
D5 KDC Miếu Nổi, Đinh Tiên Hoàng, P3, Q.Bình Thạnh
Tell : 0947 013 478 - 0914 73 81 79
Email : thuytrinh.pitesco@gmail.com
Website: www.pitesvietnam.com
Explosion proof type indicating temperature switch
Model : T990
Catalogue Download : 
Service intended
This temperature switch is installed with a micro contact, and it is suitable for measuring the temperature of corrosive fluid. Dead band is fixed.
Enclosure class
●Ex d IIB+H2 T6
●-20°C ≥ Ta ≥ 60°C
●11-AV2B0-0152X
●-20°C ≥ Ta ≥ 60°C
●11-AV2B0-0152X
Nominal diameter
125 mm
Repeatability
±1.0% of adjustable range
Accuracy
±2.0% of full scale
Measuring system (SAMA class ⅢB)
●Organic gas : 0 ~ 200°C
●Inert gas : -200 ~ 700°C
●Inert gas : -200 ~ 700°C
Working range
Maximum scale value
Location of stem
Bottom connection, surface,
Case mounting
Case mounting
Case & Cover
Silver gray finished aluminium
Capillary
●Capillary : 1.6/0.2 mm, 316SS
●Armored tube : 7.5/5.5 mm, 304SS
●Armored tube : 7.5/5.5 mm, 304SS
Switch form
●Micro contact type
●One SPDT or Two SPDT
●One DPDT
●One SPDT or Two SPDT
●One DPDT
Contact rating
●AC 125 V/250 V, 15 A and DC 30 V, 2 A
DC 125 V, 0.5 A for resistance load
● AC 125 V/250 V, 15 A and DC 30 V, 1 A
DC 125 V, 0.05 A for inductive load
DC 125 V, 0.5 A for resistance load
● AC 125 V/250 V, 15 A and DC 30 V, 1 A
DC 125 V, 0.05 A for inductive load
Stem
●8.0, 10.0 and 12.0 mm
●316SS and 316L SS
●316SS and 316L SS
Stem
●8.0, 10.0 & 12.0mm
●Stainless steel(316SS)
●Stainless steel(316SS)
Stem, process connection
⅜", ½", ¾" PT, NPT and PF
Optional
Special accuracy, ±1.0% of full scale