Công ty TNHH kỹ thuật công nghệ và dịch vụ Tiên Phong
D5 KDC Miếu Nổi, Đinh Tiên Hoàng, P3, Q.Bình Thạnh
Tell : 0947 013 478 - 0914 73 81 79
Email : thuytrinh.pitesco@gmail.com
Website: www.pitesvietnam.com
Explosion proof Sheathed thermocouple and resistance temperature detector
Model : R940 series (ETR series)
Catalogue Download : 
Service intended
Measuring the temperature in the area where combustible gas, particles and flammable liquid exist can be a very dangerous task. The electrical energy of measuring instrument is lower than electric motor, however, the malfunction of the instrument or the accident can cause to start the explosion. Therefore, ETR series is explosion proof type product which is designed to be used in a critical danger Zone 1 by acquiring IECEx and ATEX certification.
Examination certificate
●ATEX II 2G Ex d IIC T6 Gb
●IECEx Ex d IIC T6 Gb
●IECEx Ex d IIC T6 Gb
Element
●Thermocouple : K, E, J, T, N
●RTD : Pt 100Ω at 0℃
Head material
●ALDC (standard)
●316SS
●316SS
Tolerances on temperature reading
●Thermocouple
Class 1, Class 2 (DIN/IEC584-2, BS/EN60584-2, JIS C1602)
Special, Standard (ASTM E230, E988, ISA-MC96.1) ●R.T.D.
Class A : ± (0.15 + 0.002 l t l)
Class B : ± (0.3 + 0.005 l t l)
Class 1, Class 2 (DIN/IEC584-2, BS/EN60584-2, JIS C1602)
Special, Standard (ASTM E230, E988, ISA-MC96.1) ●R.T.D.
Class A : ± (0.15 + 0.002 l t l)
Class B : ± (0.3 + 0.005 l t l)
Sheath outer diameter
●Thermocouple
1.0, 1.6, 2.3, 3.2, 4.8, 6.4, 8.0, 9.5 and 12.7 mm
* Double element is not available for 1.0 and 1.6 mm
sheath outer diameter
●RTD
3.2, 4.8, 6.4 and 8.0 mm
●Ambient temperature
-40 ~ +65˚C
1.0, 1.6, 2.3, 3.2, 4.8, 6.4, 8.0, 9.5 and 12.7 mm
* Double element is not available for 1.0 and 1.6 mm
sheath outer diameter
●RTD
3.2, 4.8, 6.4 and 8.0 mm
●Ambient temperature
-40 ~ +65˚C